T4

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shandong

  • Validity to:

    Long-term effective

  • Last update:

    2017-06-25 17:58

  • Browse the number:

    325

Send an inquiries
Company Profile
Zibo Diesel Engine Parent Company
By certification [File Integrity]
Contact:

zichai(Mr.)  

Email:

Telephone:

Area:

Shandong

Address:

118# Yumin Road, Hi-tech Zone, Zibo City, China

Website: http://www.zichais.net/ http://www.extremdentremoval.com/com/zichai/
Product details

T4 series backpressure tubine is double-decked arrangement engine of the surplus heat utilization and the combined heat and power to product.While satisfies process steam,it may also obtain the inexpensive electric power.Thus energy can be used reasonable;the economic efficiency is obvious.It is used widely in enterprises,e.g.refine sugar,food chemical industry,paper making,spinning,printing and dyeing and so on.Its rotor uses a velovity-compounded stage impeller and two pressure stage.The diameter of nozzle pitch is 1050mm.Its speed regulating system is the whole hydraulic control system,multi-valve regulations,forced lubri cation.Its speed of main shaft is 3000r/min.It drags generator to generate electricity.

Trpe

B3-2.35/0.294

B3-3.43/0.49

B3-3.43/0.785

B3-3.43/0.981

B3-3.43/1.57

Rated power(kw)

3000

3000

3000

3000

3000

Cirtical speed(r/min)

1712

1669

1717

1855

5290


 

Reted condition


Inlet parameters

Pressure

3.43

3.43

3.43

3.43

3.43

temperature

435

435

435

435

435

Flow

27.27

32.1

42.45

47.8

80

Outlet parameters

Pressure

0.294

0.49

0.785

0.981

1.57

temperature

203.5

238

279

303

352

Steam consumption

9.09

10.7

14.15

15.93

25.5

High back pressure condition

Exhaust temperature

 

 

290

328

 

Steam consumption

10.63

10.7

15.2

19.65

 

Low back pressure condition outlet temperature

 

 

251

283

 

Throttle valve latus rectum

150    118X2

250    200 X    2

200    150 X    2

200    150 X    2

200    150 X    2

Exhaust latus rectum

300 X 2

300 X 2

300 X 2

350 X 1

350 X 1

Turbine/rotor weight

18.6/1.85

17.8/1.99

16.8/1.65

15.9/1.463

12.9/0.873

Install/overhaul weight

7.3  5.5

7.3    5.2

6.3    4.2

6.6    4.5

4.2    4.2

Size (mm)

3923 X 2803 X 2515

3923 X 2803 X 2515

3923 X 2803 X 2515

2923 X 2803 X 2515

3283 X 2803 X 2465

Generator type

QF-3-2

QF-3-2

QF-3-2

QF-3-2

QF-3-2

Note:The pressure of feed and exhaust steam is absolute pressure.

Trpe

B6-3.43/0.294

B6-3.343/0.49

B6-3.43/0.785

B6-3.43/0.981

B6-3.43/1.275

Rated power(kw)

6000

6000

6000

6000

6000

Cirtical speed(r/min)

1712

1667

1874

1850

2054





Reted condition

Inlet parameters

Pressure

3.43

3.43

3.43

3.43

3.43

temperature

435

435

435

435

435

Flow

51.1

57.96

80.85

86.9

118.7

Outlet parameters

Pressure

0.294

0.49

0.785

0.981

1.275

temperature

197

226

275.7

295

325

Steam consumption

8.53

9.66

12.68

14.48

18.764

High back pressure condition

Exhaust temperature

218


306

322

347

Steam consumption

9.35


15.76

17.98

23.3

Low back pressure condition outlet temperature

167



273


Throttle valve latus rectum

250 200 X 2

250 200 X 2

250 200 X 2

250 200 X 2

250 200 X 2

Exhaust latus rectum

400 X 2

300 X 2

300 X 2

300 X 2

300 X 1

Turbine/rotor weight

17.8/1.85

17.8/1.98

16.7/1.715

15.9/1.48

15.9/1.35

Install/overhaul weight

7.3  5.2

7.3 5.2

7  4.9

6.6  4.5

6.6  4.5

Size (mm)

3923 X 2803 X 2515

3923 X 2803 X 2515

3923 X 2803 X 2515

3923 X 2803 X 2515

3923 X 2803 X 2515

Generator type

QF-6-2

QF-6-2

QF-6-2

QF-6-2

QF-6-2


Note:The pressure of feed and exhaust steam is absolute pressure.

When ordering,please send us the following informations.

1.What kind of driven machinery to be used.

2.Number of units required.

3.Required output.

4.Required speed and direction of driven machinery.

5.Steam parameters:

(a)Inlet pressure

(b)Inlet temperature or superheat degree

(c)Exhaust pressure

6.Destired steam consumption

7.Required speed regulating range and foverning method.

8.Operation mode:Continuous,intermittent or spare.

9.Arrangement mode:Single-deck or double-deck,and requirements concerning the orientation of steam inlet and exhaust piping.

10.Ambient condition:Indoor or outdoor,conditions of dust and hazardous gas in air.atmospheric pressure and temperature.

11.Colling water conditions:Temperature,water quality.

Date of delivery and destination.